Use este identificador para citar ou linkar para este item: http://hdl.handle.net/11690/3676
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorDias, Nathalia Helbig-
dc.contributor.authorGomes, Douglas Rodrigues-
dc.contributor.authorOliveira, Ana Claudia Tonelli de-
dc.contributor.authorPellegrini, José Augusto Santos-
dc.contributor.authorBoniatti, Márcio Manozzo-
dc.date.accessioned2023-11-16T18:40:03Z-
dc.date.available2023-11-16T18:40:03Z-
dc.date.issued2023-
dc.identifier.citationDIAS, N. H. et al. Prognostic value of Doppler waveform analysis of common femoral vein in septic patients: a prospective cohort study. Journal of Ultrasound, v. 26, p.871–877, 2023. Disponível em: https://link.springer.com/article/10.1007/s40477-023-00819-y. Acesso em: 16 nov. 2023.pt_BR
dc.identifier.urihttp://hdl.handle.net/11690/3676-
dc.description.abstractbjectives: To assess whether there is an association between abnormal common femoral vein (CFV) Doppler waveform and intensive care unit (ICU) mortality in patients with sepsis. Methods: Patients admitted to the ICU with sepsis were included. Pulsed-wave Doppler was performed by examining the CFV in the short axis without angle correction and in the long axis with angle correction. An abnormal CFV Doppler waveform was determined by a retrograde velocity peak (RVP) > 10 cm/s in the long axis or RVP > 50% of the antegrade velocity peak in the short axis. TAPSE < 17 mm was defined as right ventricular (RV) dysfunction. The primary outcome was ICU mortality. Results: One hundred and ten patients were included. There was no association between abnormal CFV Doppler waveforms in the long (p = 0.709) and short axes (p = 0.171) and ICU mortality. TAPSE measurements were performed in 16 patients. RV dysfunction was identified in 8 (50.0%) patients. There was no association between the diagnosis of RV dysfunction based on TAPSE measurement and the identification of abnormal CFV Doppler waveforms in the long axis (p = 1.000) and in the short axis (p = 1.000). Conclusion: Abnormal CFV Doppler waveforms were not associated with ICU mortality in patients with sepsis. Furthermore, in the exploratory analysis, these alterations were not useful in identifying RV dysfunction in these patients.pt_BR
dc.language.isootherpt_BR
dc.subjectCommon femoral veinpt_BR
dc.subjectDoppler ultrasoundpt_BR
dc.subjectPulsatilitypt_BR
dc.subjectRight atrial pressurept_BR
dc.subjectRight ventricular dysfunctionpt_BR
dc.subjectSepsispt_BR
dc.titlePrognostic value of Doppler waveform analysis of common femoral vein in septic patients: a prospective cohort studypt_BR
dc.typeOtherpt_BR
Aparece nas coleções:Artigo de Periódico (PPGSDH)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
s40477-023-00819-y.pdfOpen Access1,52 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.