DSpace Repository

Bundle of Coated Devices to Reduce Nosocomial Infections in the Intensive Care Unit: CRITIC Pilot Randomized Controlled Trial

Show simple item record

dc.contributor.author Zampieri, Fernando G.
dc.contributor.author Oliveira, Neymar Elias de
dc.contributor.author Nassar Junior, Antonio Paulo
dc.contributor.author Manoel, Airton Leonardo de Oliveira
dc.contributor.author Grion, Cintia
dc.contributor.author Lacerda, Fábio H.
dc.contributor.author Maia, Israel
dc.contributor.author Thompson, Marlus
dc.contributor.author Giancursi, Thiago Simões
dc.contributor.author Martins, Priscilla de Aquino
dc.contributor.author Lisboa, Thiago
dc.contributor.author Abait, Tamiris
dc.contributor.author Damiani, Lucas P.
dc.contributor.author Machado, Flávia R.
dc.contributor.author Cavalcanti, Alexandre B.
dc.date.accessioned 2021-07-23T16:14:43Z
dc.date.available 2021-07-23T16:14:43Z
dc.date.issued 2020
dc.identifier.citation ZAMPIERI, F. G. et al. Bundle of Coated Devices to Reduce Nosocomial Infections in the Intensive Care Unit: CRITIC Pilot Randomized Controlled Trial. ATS Journals, v. 17, n. 10, p. 1257-1263, out. 2020. Disponível em: https://www.atsjournals.org/doi/pdf/10.1513/AnnalsATS.202003-206OC. Acesso em: 23 jul. 2021. pt_BR
dc.identifier.uri http://hdl.handle.net/11690/1891
dc.description.abstract Rationale: Coated devices may reduce biofilm formation and reduce the occurrence of device-related infections in critically ill patients. A bundle of coated devices (an endotracheal tube [ETT], central venous catheter [CVC], and urinary catheter [UC]) simultaneously inserted may optimize benefits of coated devices in patients with the most severe illness.Objectives: To assess the feasibility of a randomized controlled trial on simultaneous insertion of gold/silver/palladium-coated devices versus uncoated devices in severely ill patients, which required sequential insertion of all three devices (an ETT, CVC, and UC) for support in the intensive care unit (ICU).Methods: This was a multicenter randomized controlled pilot trial. Patients who required simultaneous insertion of an ETT, CVC, and UC were randomized to treatment with coated versus uncoated devices, which were used as necessary for up to 28 days. The primary endpoint was feasibility, defined as the trial being able to enroll enough participants to have the sample size necessary for its secondary primary endpoint (estimating sepsis incidence in this population) in less than 1 year and for estimating the number of admitted patients who require simultaneous insertion of all three devices. Secondary endpoints included the incidence of sepsis and device-associated infections (ventilator-associated pneumonia, catheter-related bloodstream infection, and catheter-related urinary-tract infection) within each group as well as the number of days alive and free of antibiotics during the ICU stay. All events were adjudicated.Results: One hundred and three patients (48 in the coated-device group and 55 in the uncoated-device group) were included in the per-protocol analysis. The inclusion period was 8 months. There were 13 septic events in each group (26 in total), with an approximate incidence of sepsis of 32.3 (95% credible interval [CrI], 22.4-44.9) per 100 patient-days. The overall incidences of ventilator-associated pneumonia, catheter-related urinary-tract infection, and catheter-related bloodstream infection were 15.2 (95% CrI, 7.8-26.4), 6.3 (95% CrI, 2.4-13.7), and 7.9 (95% CrI, 3.6-15.1) per 1,000 patient-days, and incidence rates were not statistically different between groups. Patients in the coated-device group had more days alive and free of antibiotics in the ICU (28.97 d vs. 19.62 d per 100 patient-days; mean ratio, 1.48; 95% CrI, 1.16-1.89).Conclusions: Use of a bundle of coated devices as the initial treatment for of severely ill patients is feasible. Coated devices may be associated with more days alive and free of antibiotics.Clinical trial registered with www.clinicaltrials.gov (NCT03868241). pt_BR
dc.language.iso en_US pt_BR
dc.publisher American Thoracic Society pt_BR
dc.rights Closed Access en
dc.subject Coated devices pt_BR
dc.subject Health care–associated infections pt_BR
dc.subject Sepsis pt_BR
dc.subject Ventilator-associated pneumonia pt_BR
dc.title Bundle of Coated Devices to Reduce Nosocomial Infections in the Intensive Care Unit: CRITIC Pilot Randomized Controlled Trial pt_BR
dc.type Artigo pt_BR


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account